http://www.cnr.it/ontology/cnr/individuo/prodotto/ID307388
Functional tomography using a time-gated ICCD camera (Articolo in rivista)
- Type
- Label
- Functional tomography using a time-gated ICCD camera (Articolo in rivista) (literal)
- Anno
- 2011-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1364/BOE.2.000705 (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Zhao Q.; Spinelli L.; Bassi A.; Valentini G.; Contini D.; Torricelli A.; Cubeddu R.; Zaccanti G.; Martelli F.; Pifferi A. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://www.scopus.com/inward/record.url?eid=2-s2.0-84855452602&partnerID=q2rCbXpz (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Dept Robotics Brain and Cognitive Sciences, Istituto Italiano di Tecnologia, via Morego 30, I-16163 Genova, Italy; Istituto di Fotonica e Nanotecnologie, Sezione di Milano, Consiglio Nazionale delle Ricerche, piazza Leonardo da Vinci 32, I-20133 Milan, Italy; Dipartimento di Fisica, Politecnico di Milano, piazza Leonardo da Vinci 32, 20133 Milan, Italy; Dipartimento di Fisica e Astronomia, Università degli Studi di Firenze, via G. Sansone 1, 50019 Sesto Fiorentino, Firenze, Italy (literal)
- Titolo
- Functional tomography using a time-gated ICCD camera (literal)
- Abstract
- We present a system for near infrared functional tomography based on a single pulsed source and a time-gated camera, for non-contact collection over a large area. The mean penetration depth of diffusely reflected photons is dependent on the arrival time of photons, but not on the source-detector distance. Thus, time-encoded data can be used to recover depth information while photon exiting point is exploited for lateral localization. This approach was tested against simulations, demonstrating both detection and localization capabilities. Preliminary measurements on inhomogeneous phantoms showed good detection sensibility, even for a low optical perturbation, and localization capabilities, yet with decreasing spatial resolution for increasing depths. Potential application of this method to in vivo functional studies on the brain is discussed. © 2011 Optical Society of America. (literal)
- Prodotto di
- Autore CNR
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi