AbstractThe exposure of a 8-years child to a 4G LTE femtocell, both (child and source) freely located in random positions in a realistic indoor environment was assessed by sparse low rank tensor approximation method (sparse LRA) for developing stochastic dosimetry by surrogate models. These latters were used for fast estimating the Specific Absorption Rate (SAR) in all the possible positions of femtocell and child and to assess the compliance with the International Commission of Non-Ionizing Radiation Protection (ICNIRP) guidelines for general public exposure. Results showed that, for all the possible positions in the room, the exposure values were significantly below the ICNIRP guidelines and that the probability of reaching SAR values higher than 1% of the ICNIRP guidelines value was lower than 0.006. The variation of the distance between femtocell and child influenced greatly the exposure, resulting in Quartile Coefficient of Dispersion values always higher than 48 %.
Lingua abstractinglese
Altro abstract-
Lingua altro abstract-
Pagine da-
Pagine a-
Pagine totali-
RivistaIEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
ISSN: 2469-7249
Titolo chiave: IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Numero volume della rivista-
Fascicolo della rivista-
DOI-
Verificato da refereeSì: Internazionale
Stato della pubblicazionePreprint
Indicizzazione (in banche dati controllate)-
Parole chiaveStochastic Dosimetry, Low RankTensor approximations, WLAN
Link (URL, URI)-
Titolo parallelo-
Data di accettazione-
Note/Altre informazioni-
Strutture CNR
  • IEIIT — Istituto di elettronica e di ingegneria dell'informazione e delle telecomunicazioni
Moduli CNR-
Progetti Europei-
Allegati