@prefix pubblicazioni: . @prefix unitaDiPersonaleInterno: . @prefix prodotto: . unitaDiPersonaleInterno:MATRICOLA42109 pubblicazioni:autoreCNRDi prodotto:ID62741 . unitaDiPersonaleInterno:MATRICOLA5478 pubblicazioni:autoreCNRDi prodotto:ID62741 . unitaDiPersonaleInterno:MATRICOLA5515 pubblicazioni:autoreCNRDi prodotto:ID62741 . @prefix prodottidellaricerca: . @prefix istituto: . istituto:CDS035 prodottidellaricerca:prodotto prodotto:ID62741 . @prefix modulo: . modulo:ID6308 prodottidellaricerca:prodotto prodotto:ID62741 . modulo:ID6306 prodottidellaricerca:prodotto prodotto:ID62741 . @prefix rdf: . @prefix retescientifica: . prodotto:ID62741 rdf:type retescientifica:ProdottoDellaRicerca , prodotto:TIPO1101 . @prefix rdfs: . prodotto:ID62741 rdfs:label "Cardiac functional stress imaging: a sequential approach with stress echo and cardiovascular magnetic resonance (Articolo in rivista)"@en . @prefix xsd: . prodotto:ID62741 pubblicazioni:anno "2007-01-01T00:00:00+01:00"^^xsd:gYear . @prefix skos: . prodotto:ID62741 skos:altLabel "
Sicari R.; Pingitore A.; Aquaro G. D.; Pasanisi E. M.; Lombardi M.; Picano E. (2007)
Cardiac functional stress imaging: a sequential approach with stress echo and cardiovascular magnetic resonance
in Cardiovascular ultrasound
"^^rdf:HTML ; pubblicazioni:autori "Sicari R.; Pingitore A.; Aquaro G. D.; Pasanisi E. M.; Lombardi M.; Picano E."^^xsd:string ; pubblicazioni:numeroVolume "5"^^xsd:string . @prefix ns11: . prodotto:ID62741 pubblicazioni:rivista ns11:ID74883 ; pubblicazioni:note "In: Cardiovascular Ultrasound, vol. 5 (1) pp. 47 - 51. Biomed Central, 2007."^^xsd:string ; pubblicazioni:affiliazioni "Istituto di Fisiologia Clinica del CNR"^^xsd:string ; pubblicazioni:titolo "Cardiac functional stress imaging: a sequential approach with stress echo and cardiovascular magnetic resonance"^^xsd:string ; prodottidellaricerca:abstract "ABSTRACT: AIMS: The aim of the study was to assess the feasibility and accuracy of an integrated stress imaging algorithm with echo first and second-line cardiac magnetic resonance (CMR) in selected cases. Stress echo (SE) is widely used for non-invasive diagnosis of coronary artery disease (CAD), but difficult patients and ambiguous responses may be met even with top-level technology and expertise. CMR might ideally complement SE in well-selected cases with unfeasible and/or ambiguous and/or submaximal results. Methods and results: 152 in-hospital patients with chest pain and normal baseline function were referred for SE and coronary angiography. Of the initial population, 33 were shunted to CMR due to poor acoustic window or ambiguous or submaximal SE test. The only criterion of positivity for both techniques was the presence of regional wall motion abnormalities in at least 2 contiguous segments. Coronary angiography was performed independently of test results. Significant CAD was identified by a 50% quantitatively assessed diameter reduction in at least 1 major coronary vessel. CAD was present in 88 patients. Interpretable and diagnostic stress test were obtained in 143 patients with the sequential algorithm. The sequential (SE in 110 + CMR in 33 patients) algorithm showed a sensitivity of 76% (95% CI 66% to 85%) specificity of 87% (95% CI 76% to 95%) and accuracy of 80% (95% CI 73% to 86%). CONCLUSION: A sequential functional stress imaging algorithm with stress echo first and stress CMR in selected cases is feasible, clinically realistic and allows an efficient, radiation-free diagnosis of CAD."@en ; prodottidellaricerca:prodottoDi modulo:ID6306 , istituto:CDS035 , modulo:ID6308 ; pubblicazioni:autoreCNR unitaDiPersonaleInterno:MATRICOLA42109 , unitaDiPersonaleInterno:MATRICOLA5478 , unitaDiPersonaleInterno:MATRICOLA5515 . @prefix parolechiave: . prodotto:ID62741 parolechiave:insiemeDiParoleChiave . ns11:ID74883 pubblicazioni:rivistaDi prodotto:ID62741 . parolechiave:insiemeDiParoleChiaveDi prodotto:ID62741 .