@prefix prodottidellaricerca: . @prefix istituto: . @prefix prodotto: . istituto:CDS063 prodottidellaricerca:prodotto prodotto:ID39810 . @prefix pubblicazioni: . @prefix unitaDiPersonaleInterno: . unitaDiPersonaleInterno:MATRICOLA9215 pubblicazioni:autoreCNRDi prodotto:ID39810 . @prefix modulo: . modulo:ID2686 prodottidellaricerca:prodotto prodotto:ID39810 . @prefix rdf: . @prefix retescientifica: . prodotto:ID39810 rdf:type retescientifica:ProdottoDellaRicerca , prodotto:TIPO1101 . @prefix rdfs: . prodotto:ID39810 rdfs:label "Orientation of the DMPC Unilamellar Vesicle System in the Magnetic Field: SANS Study (Articolo in rivista)"@en . @prefix xsd: . prodotto:ID39810 pubblicazioni:anno "2008-01-01T00:00:00+01:00"^^xsd:gYear . @prefix skos: . prodotto:ID39810 skos:altLabel "
Kiselev M. A. (1); T. Gutberlet(2); A. Hoell(3); V.L. Aksenov(1); D. Lombardo(4) (2008)
Orientation of the DMPC Unilamellar Vesicle System in the Magnetic Field: SANS Study
in Chemical physics (Print)
"^^rdf:HTML ; pubblicazioni:autori "Kiselev M. A. (1); T. Gutberlet(2); A. Hoell(3); V.L. Aksenov(1); D. Lombardo(4)"^^xsd:string ; pubblicazioni:paginaInizio "181"^^xsd:string ; pubblicazioni:paginaFine "184"^^xsd:string ; pubblicazioni:numeroVolume "345"^^xsd:string . @prefix ns11: . prodotto:ID39810 pubblicazioni:rivista ns11:ID336555 ; skos:note "ISI Web of Science (WOS)"^^xsd:string ; pubblicazioni:affiliazioni "(1) FLNP, Joint Institute for Nuclear Research, Dubna, Russia, \n(2) Paul Scherrer Institute, 5232 Villigen PSI, Switzerland\n(3) Hahn-Meitner-Institute Berlin, Germany, \n(4) Istituto per i Processi Chimico Fisici (IPCF-CNR), Sez. Messina, Italy"^^xsd:string ; pubblicazioni:titolo "Orientation of the DMPC Unilamellar Vesicle System in the Magnetic Field: SANS Study"^^xsd:string ; prodottidellaricerca:abstract "We present the results of a Small Angle Neutron Scattering investigation on a unilamellar DMPC vesicle system during the application of a magnetic field. The presence of the strong magnetic field, elongate the vesicles along the field and cause a change in the shape of the particles. This circumstance is caused by the presence of a small anisotropy in the magnetic susceptibility parallel and perpendicular to the long axes of phospholipid molecules. Our obtained results indicate the importance of some relevant parameters such as the vesicle dimension and concentrations. More specifically under the action of a strong magnetic field (H= 4T) small (50 nm diameter) vesicles show a shape modification from sphere to ellipsoid. On the other hand the increase in vesicle dimensions (up to 200 nm diameter) as well as at the higher DMPC concentration (i.e. C=5% w/w) vesicle magnetic deformation is hindered. The main structural modification of the system has been explained as the effect of increasing of the effective \u0093steric stability\u0094 for the system against the deforming action of an external perturbation. The use of magnetic forces can be seen as a promising tool for noninvasive manipulation"@en ; prodottidellaricerca:prodottoDi istituto:CDS063 , modulo:ID2686 ; pubblicazioni:autoreCNR unitaDiPersonaleInterno:MATRICOLA9215 . ns11:ID336555 pubblicazioni:rivistaDi prodotto:ID39810 .