@prefix prodottidellaricerca: . @prefix istituto: . @prefix prodotto: . istituto:CDS053 prodottidellaricerca:prodotto prodotto:ID273583 . @prefix pubblicazioni: . @prefix unitaDiPersonaleInterno: . unitaDiPersonaleInterno:MATRICOLA6038 pubblicazioni:autoreCNRDi prodotto:ID273583 . @prefix modulo: . modulo:ID8646 prodottidellaricerca:prodotto prodotto:ID273583 . unitaDiPersonaleInterno:MATRICOLA11383 pubblicazioni:autoreCNRDi prodotto:ID273583 . @prefix rdf: . @prefix retescientifica: . prodotto:ID273583 rdf:type retescientifica:ProdottoDellaRicerca , prodotto:TIPO1101 . @prefix rdfs: . prodotto:ID273583 rdfs:label "Pressurized nano-liquid-junction interface for coupling capillary electrochromatography and nano-liquid chromatography with mass spectrometry. (Articolo in rivista)"@en . @prefix xsd: . prodotto:ID273583 pubblicazioni:anno "2013-01-01T00:00:00+01:00"^^xsd:gYear ; pubblicazioni:doi "10.1016/j.chroma.2013.08.052"^^xsd:string . @prefix skos: . prodotto:ID273583 skos:altLabel "
G. D'Orazio, S. Fanali (2013)
Pressurized nano-liquid-junction interface for coupling capillary electrochromatography and nano-liquid chromatography with mass spectrometry.
in Journal of chromatography (Print)
"^^rdf:HTML ; pubblicazioni:autori "G. D'Orazio, S. Fanali"^^xsd:string ; pubblicazioni:paginaInizio "67"^^xsd:string ; pubblicazioni:paginaFine "76"^^xsd:string ; pubblicazioni:numeroVolume "1317"^^xsd:string . @prefix ns11: . prodotto:ID273583 pubblicazioni:rivista ns11:ID294073 ; pubblicazioni:pagineTotali "10"^^xsd:string ; pubblicazioni:affiliazioni "Istituto di Metodologie Chimiche (IMC), Consiglo Nazionale delle Ricerche"^^xsd:string ; pubblicazioni:titolo "Pressurized nano-liquid-junction interface for coupling capillary electrochromatography and nano-liquid chromatography with mass spectrometry."^^xsd:string ; prodottidellaricerca:abstract "A new nano-liquid-junction interface for coupling both capillary electrochromatography (CEC) or nano-liquid chromatography (nano-LC) with mass spectrometry (MS) was studied. The interface was a smallT piece of polymeric material where capillary column and tip capillary were positioned at 180owhilethe third exit (at 90o) was occupied by a capillary delivering a liquid-assisting spray ionization for CECexperiments or by the electrode for the high voltage spray for nano-LC. Experiments were carried outanalyzing mixtures of some organophosphorus pesticides (OPPs) or anti-inflammatory and related acidicdrugs with MS detection in positive or negative ion mode, respectively. Analyzed OPPs compounds werebaseline resolved utilizing the novel interface in both nano-LC and CEC obtaining good sensitivity andrepeatability. For CEC-MS, the limits of detection ranged between 0.03 and 6.80 ?g/mL and the intra-dayrepeatability was RSD <3.8% and <13% for the retention times and peak areas, respectively. The interfacewas easy to handle and good reproducibility, between 2.5 and 3.5% for the retention time and <10% forthe efficiencies, was obtained when the interface was installed by two different analysts. Furthermore, itcould be used for both CEC and nano-LC."@en ; prodottidellaricerca:prodottoDi istituto:CDS053 , modulo:ID8646 ; pubblicazioni:autoreCNR unitaDiPersonaleInterno:MATRICOLA11383 , unitaDiPersonaleInterno:MATRICOLA6038 . @prefix parolechiave: . prodotto:ID273583 parolechiave:insiemeDiParoleChiave . ns11:ID294073 pubblicazioni:rivistaDi prodotto:ID273583 . parolechiave:insiemeDiParoleChiaveDi prodotto:ID273583 .