@prefix prodottidellaricerca: . @prefix istituto: . @prefix prodotto: . istituto:CDS053 prodottidellaricerca:prodotto prodotto:ID197406 . @prefix pubblicazioni: . @prefix unitaDiPersonaleInterno: . unitaDiPersonaleInterno:MATRICOLA6038 pubblicazioni:autoreCNRDi prodotto:ID197406 . @prefix modulo: . modulo:ID8646 prodottidellaricerca:prodotto prodotto:ID197406 . @prefix rdf: . prodotto:ID197406 rdf:type prodotto:TIPO1101 . @prefix retescientifica: . prodotto:ID197406 rdf:type retescientifica:ProdottoDellaRicerca . @prefix rdfs: . prodotto:ID197406 rdfs:label "Quality control of benserazide-levodopa and carbidopa-levodopa tablets by capillary zone electrophoresis (Articolo in rivista)"@en . @prefix xsd: . prodotto:ID197406 pubblicazioni:anno "2000-01-01T00:00:00+01:00"^^xsd:gYear . @prefix skos: . prodotto:ID197406 skos:altLabel "
Fanali S, Pucci V, Sabbioni C, Raggi MA (2000)
Quality control of benserazide-levodopa and carbidopa-levodopa tablets by capillary zone electrophoresis
in Electrophoresis (Weinh., Print)
"^^rdf:HTML ; pubblicazioni:autori "Fanali S, Pucci V, Sabbioni C, Raggi MA"^^xsd:string ; pubblicazioni:paginaInizio "2431"^^xsd:string ; pubblicazioni:paginaFine "2437"^^xsd:string ; pubblicazioni:numeroVolume "21"^^xsd:string . @prefix ns11: . prodotto:ID197406 pubblicazioni:rivista ns11:ID416656 ; skos:note "PubMe"^^xsd:string ; pubblicazioni:affiliazioni "IMC-CNR; University of Bologna; University of Bologna;University of Bologna;University of Bologna;"^^xsd:string ; pubblicazioni:titolo "Quality control of benserazide-levodopa and carbidopa-levodopa tablets by capillary zone electrophoresis"^^xsd:string ; prodottidellaricerca:abstract "In modern practice, the treatment of Parkinson's disease and syndrome is carried out using pharmaceutical formulations containing a combination of levodopa and a decarboxylation inhibitor (carbidopa or benserazide). Two pharmaceutical formulations were quantified by capillary zone electrophoresis using two procedures which differed only in the kind of background electrolyte used. One procedure used a 25 mM phosphate buffer, pH 2.5, while the second one used a 25 mM borate buffer, pH 8.5. The electrophoretic analysis was carried out using an uncoated fused- silica capillary, a separation voltage of 20 kV with currents typically less than 60 ?A, and spectrophotometric detection at 205 nm. Calibration curves were performed for levodopa (concentration range 1-100 ?g/mL), for carbidopa and benserazide (1-50 ?g/mL), and the plots of the peak area versus concentration were found to be linear with a correlation coefficient better than 0.9990. Satisfactory results were obtained when commercial tablets were analyzed in terms of accuracy (98-102%), repeatability (0.6-2.0%), and intermediate precision (1.1-2.6%). \u00A9 WILEY-VCH Verlag GmbH, 2000."@en ; prodottidellaricerca:prodottoDi modulo:ID8646 , istituto:CDS053 ; pubblicazioni:autoreCNR unitaDiPersonaleInterno:MATRICOLA6038 . ns11:ID416656 pubblicazioni:rivistaDi prodotto:ID197406 .