Titolo: Standardization of a European measurement method for the determination of total gaseous mercury: results of the field trial campaign and determination of a measurement uncertainty and working range

Anno di pubblicazione: 2010

Formato: Cartaceo

Autori: Brown, R.J.C., Pirrone, N. van Hoek, C. Sprovieri, F., Fernandez, R. and Tote, K.

Affiliazioni autori: Brown, R.J.C. (a), Pirrone, N. (b) van Hoek, C. (c) Sprovieri, F. (d), Fernandez, R. (e) and Tote, K. (f) a) Analytical Science Team, National Physical Laboratory, Teddington, Middlesex, UK TW11 0LW. b) CNR IIA, CNR-Institute of Atmospheric Pollution Research, Rome, Italy c) NEN, Dutch Standardization Institute, Delft, Netherlands d) CNR IIA, CNR-Institute of Atmospheric Pollution Research, Rende, Italy e) Instituto de Salud Carlos III, Majadahonda, Madrid, Spain f) The Flemish Environment Agency, VMM, Antwerp, Belgium

Autori CNR:

  • NICOLA PIRRONE
  • FRANCESCA SPROVIERI

Lingua: inglese

Abstract: Working Group 25 of the European Committee for Standardisation's (CEN) Technical Committee 264 - 'Air Quality' is currently finalising a standard method for the measurement of total gaseous mercury (TGM) in ambient air, in response to the requirements of the European Union's Fourth Air Quality Daughter Directive (4th DD). We report the results of a programme of field measurements and the statistical analysis performed to assess the uncertainty of the proposed standard method, define its working range and determine its compliance with the required data quality objectives of the Fourth Air Quality Daughter Directive. The statistical analysis has shown that the maximum relative expanded uncertainty of 50% allowed by the 4th DD is met down to a mercury mass concentration of approximately 0.75 ng m3, and that the dominant contribution to this uncertainty is systematic bias between instruments, mainly arising from the uncertainty in the calibration of the instruments.

Lingua altro abstract: inglese

Pagine da: 689

Pagine a: 695

Pagine totali: 7

Rivista:

Journal of environmental monitoring Royal Society of Chemistry,
Paese di pubblicazione: Regno Unito
Lingua: inglese
ISSN: 1464-0325

Numero volume: 12

Numero fascicolo: 3

DOI: 10.1039/b924955a

Referee: Sė: Internazionale

Indicizzato da: ISI Web of Science (WOS) [000275471200015]

Parole chiave:

  • GEM
  • measurement
  • air
  • intercomparison
  • CEN standard

URL: http://www.rsc.org/jem